A unit that needs gas every few months has a leak. We find it, repair it and recharge correctly, so you stop paying for the same refrigerant twice.

How is a refrigerant leak found?

A refrigerant leak is found with an electronic leak detector along joints, coils and valves, and confirmed by pressure testing the circuit with dry nitrogen and checking for pressure loss. Once repaired, the circuit is pressure-tested again, evacuated with a vacuum pump and recharged to the manufacturer's charge by weight.

Reviewed by the MSTECK engineering team · Updated

What We Do

Leak Detection and Repair Scope

Topping up a leaking unit only buys time. Finding and repairing the leak saves the refrigerant, the compressor and the repeat call-outs.

  • Electronic leak detection: joints, coils, flare nuts and service valves.
  • Nitrogen pressure testing: to confirm a leak and prove the repair.
  • Repair: brazed joints, flare connections, valves and coil leaks.
  • Vacuum and recharge: evacuated and charged by weight to the manufacturer's figure.
  • Units covered: split, ducted split and package units.

Get a Leak Detection Quote

An engineer reviews every request and replies with an approach and a quote.

Please enter your name.
Please enter your phone number.
Please enter your email address.
Please tell us briefly what you need.

By sending this form you agree to our Privacy Policy.

Prefer to message us directly?

Signs You Need It

Signs of a Refrigerant Leak

Repeated Regassing

Units that lose cooling every few months and keep needing gas.

Oil Marks or Ice

Oily stains at joints or ice on pipes and coils.

Package Units

Rooftop and package units with falling performance.

How We Work

How a Leak Repair Runs

  1. Detect. Electronic detection along the circuit to find the leak.
  2. Confirm. Nitrogen pressure test to confirm and locate it.
  3. Repair. The joint, valve or coil is repaired.
  4. Prove and recharge. Pressure test, vacuum and recharge by weight.
Questions

Frequently Asked Questions

Why does my AC keep needing gas?

Because the refrigerant is leaking out. Refrigerant is not used up in normal running, so a unit that needs topping up has a leak somewhere.

Which units do you work on?

Split, ducted split and package units.

Do you recharge by weight?

Yes. After a repair the circuit is evacuated and charged by weight to the manufacturer's figure.