HVAC Noise & Vibration Diagnostics

A noisy AHU, a humming FCU above a bedroom or a pump you can feel through the floor. We find the cause and fix it, rather than hide it.

What causes HVAC noise and vibration?

Most HVAC noise and vibration comes from a short list of causes: fan or motor imbalance, worn bearings, misaligned belts or couplings, failed anti-vibration mounts, resonance in a frame or duct, high air velocity at outlets, or pumps running off their duty point. Diagnosis means measuring and listening to find which one, before anything is replaced.

Reviewed by the MSTECK engineering team · Updated

What We Diagnose

Noise and Vibration Problems We Diagnose

Lining a duct or adding a silencer can hide a noise for a while. Finding the mechanical cause fixes it and usually saves the equipment too.

  • Fans and motors: imbalance, bearings, belts, pulleys and alignment.
  • Anti-vibration mounts: failed or bypassed mounts and flexible connections.
  • Ducts: high velocity, rattling, drumming and regenerated noise at fittings.
  • Pumps: vibration, cavitation and pipe-borne noise.
  • FCUs and AHUs: noise into occupied rooms from units above ceilings.

Get a Diagnostics Quote

An engineer reviews every request and replies with an approach and a quote.

Please enter your name.
Please enter your phone number.
Please enter your email address.
Please tell us briefly what you need.

By sending this form you agree to our Privacy Policy.

Prefer to message us directly?

Typical Jobs

Typical Noise and Vibration Jobs

Noisy Units Above Rooms

FCUs and ducted units heard in bedrooms, offices and meeting rooms.

Rooftop and Plant Room Noise

AHUs, fans and pumps heard or felt in occupied floors.

Rising Vibration

Equipment that has started vibrating more, a common early sign of wear.

How We Work

How a Diagnostics Job Runs

  1. Listen and measure. Noise and vibration are recorded at the source and where they are heard.
  2. Inspect. Fans, bearings, belts, mounts, ducts and pipe connections are checked.
  3. Find the cause. The measurements and inspection point to the root cause.
  4. Fix and re-measure. We correct the fault and measure again to confirm the result.
Questions

Frequently Asked Questions

Why is my AHU or FCU so noisy?

Common causes are fan imbalance, worn bearings, loose panels, failed anti-vibration mounts or high airflow through small outlets. We measure to find which.

Can you reduce noise without replacing the unit?

Usually, yes. Most noise problems are fixed by correcting the cause, such as balancing a fan, replacing bearings or mounts, or slowing the air.

Do you check pumps as well?

Yes, for vibration, cavitation and noise carried through the pipework.

Which areas do you cover?

Projects across the UAE, including Dubai, Sharjah, Ajman and Abu Dhabi, run from our office in Al Qusais Industrial Area 5, Dubai.

Get a Quote for Your Project

Pipe size, system, location in the building and when it needs doing. Photos help. An engineer replies with an approach and a price.